DCS 416R

Analog input & output interface module

Summary & Images Specs Downloads & Support

The module provides analogue input and output interfacing capabilities for use in monitoring and control functions. Both inputs and outputs are capable of handling 0 to 10 VDC with 256 distinct levels. Potentiometers for volume control can be interfaced using the provided reference voltage output. The modules have CE marking as well as UL and CSA recognition for DCS 416.

Specifications

Operating voltage 24 V DC, -10%/+30%
Operating current (max.) Standby/Idle/Announcement/Alert: 24 V, 72 mA, 1.73 W
Electromagnetical environment E1, E2, E3

Operating temperature -5 °C to 45 °C
Product dimensions (Width by Height by Depth) 37.5 by 80.6 by 245 mm
Net weight 170 g
Inputs Voltage range (min.–max.) 0–10 V DC
Impedance range ext.(min.–max.) 0–10 kΩ
Maximum input voltage 50 V DC
Outputs Voltage range (min.–max.) 0–10 V DC
Output impedance 47 Ω
Maximum load 2 kΩ
Resolution of inputs/outputs 8 Bit
Reference voltage source Output voltage 10 V DC
Maximum output current 30 mA

Let's talk

Dynacord & Electro-Voice, together with our certified partners, are ready to help support you through planning, purchase, and setup. Services available through our network of highly-qualified associates and partners may include:

  • System Design
  • Installation
  • Programming & Commissioning

Find your local contact

Downloads

Warranty & After Sales Programs

Compatible Products

sprites_global sprites_ev