RCM-810
Iris‑net module for dsa series power amplifiers
IRIS-Net module for remote control and supervision of DSA Series power amplifiers.
This module provides very cost-effective integration of all 2-, 4- and 8- channel DSA Series power amplifiers into IRIS-Net networks allowing comprehensive remote control and supervision.
Control features are: Configuration, Power ON/OFF, Power On Delay, Mute, Variable Load Drive
Supervision parameters are: Load supervision for each channel, Output VU, Protect, Limit, Pilot tone, Temperature, Gain/Sensitivity.
In addition a GPIO block allows for 2 Control Inputs, 2 Control Outputs, 2 Reference Outputs (+5 V, 200 mA / GND)
Specifications
Remote control & software | IRIS-Net, Multiple PCs possible, MS Windows 2000, XP, Vista, 7,8 | |||
Maximum configuration | 250 Amplifiers in total, 100 Amplifiers per CAN bus, 1000 meter cable run | |||
Amplifier supervision | Operation mode, temperature, output voltage & current, impedance of connected speakers, protection mode status, pilot tone detection | |||
Specifications |
Network supervision | CAN bus failures, defective or missing amplifiers, bandwidth, failure protocol & messaging |
CAN interface | 10–500 kbaud, 2 x RJ-45 (IRISNet Control) |
GPIO control port | 2 x 3-pole Euro block
|
Supply voltage/current | +5 V DC / 320 mA +15 V DC / 80 mA -15 V DC / 80 Ma |
Power consumption | 4 W |
Electromagnetical environment | E1, E2, E3 |
Operating temperature | 0 °C to 40 °C |
Product dimensions (Width xHeight x Depth) | 103.5 x 37 x 103 mm |
Net weight | 115 g |