DCS 412R

Inputs module

Summary & Images Specs Downloads & Support

The module provides inputs for control lines, pushbuttons, switches and sensors allowing the evaluation of their individual status (on/off) in the DPM 4000 system. The modules have CE marking as well as UL and CSA recognition for DCS 412.

产品规格

Operating voltage 24 V DC, -10%/+30%
Operating current, all inputs open Standby/Idle/Announcement/Alert: 24 V, 83 mA, 2.00 W
Electromagnetical environment E1, E2, E3
Operating temperature -5 °C to 45 °C

Product dimensions (Width by Height by Depth) 37.5 by 80.6 by 245 mm
Net weight 175 g
Input level Input voltage for off (Low)U_IN < ±5 V
Input voltage for on (High) U_IN > ±10 V
Input current at U_IN = 24 V I_IN = 4.8 mA
Input voltage max. U_IN max = ±31 V
Output source 24 V Output current max: 90 mA

下载

Let's talk

Dynacord & Electro-Voice, together with our certified partners, are ready to help support you through planning, purchase, and setup. Services available through our network of highly-qualified associates and partners may include:

  • System Design
  • Installation
  • Programming & Commissioning

Find your local contact

售后及相关政策

Compatible Products

sprites_global sprites_ev