IPX5:4

4 x 1250 w multi‑channel installation dsp class‑d amplifier

Summary & Images Specs Downloads & Support
  • 4 x 1250 W multi-channel installation DSP amplifier with digitally controlled PFC supply.
  • Fully integrated DSP with high-resolution 96 kHz processing and FIR Drive.
  • Dante and OCA integration via OMNEO with fallback options.
  • Parallel, bridged and parallel-bridged drive modes with 70/100V/140V/200V and low impedance operation
  • High efficiency ecoRAIL technology for lower operating costs

IPX Series are dedicated amplifiers for fixed install application such as e.g. stadiums, arenas, houses of worship, concert halls, theaters and other applications that require high‑power multichannel amplifiers with sophisticated speaker processing. The integrated DSP can run either in 48 kHz or true 96 kHz including FIR Drive. Besides analog inputs also Dante and OCA via OMNEO network inputs are available. Comprehensive fallback options allow redundant scenarios.

Each channel can be individually operated in low impedance mode, or 70V/100V Direct Drive mode. By bridging also 140V/200V Direct Drive is available. By the possibility to parallel two channels and parallel‑bridge four channels all kind of loudspeakers can be driven.

Due to the digitally controlled interleaved PFC supply reliable operation is ensured even under challenging mains supply situations. Reactive current is limited to a minimum, which reduces costs for mains installations and mains fusing in the installation.

In case of idle mode or light mode operation IPX Series amplifiers automatically switch to a lower ecoRAIL further reducing operating costs. In Eco Mode the amplifiers stay fully functional and supervised.

While IPX Series amplifiers are fully integrated in IRIS‑Net, a OLED display on the front panel allows quick local control and supervision of the amplifier.

The connectivity of IPX Series amplifiers is optimized for fixed install applications.

Specifications

Amplifier Model IPX5:4
OUTPUT POWER
Low-Z mode: Load Impedance 2Ω 2.7Ω 4Ω 8Ω
Maximum Output Power1
Normal Mode, all channels driven 1300 W 1500 W 1250 W 1250 W
Bridged - - 2600 W 2500 W
Parallel 2500 W 3000 W 2500 W 1250 W
Parallel-Bridged 5200 W 6000 W 5000 W 5000 W
Direct Drive Mode: Nominal Voltage 70 V 100 V 140 V2 200 V2
Maximum Output Power1 1250 W 1250 W 2500 W 2500 W
Number of amplifier channels 4
Maximum Output Voltage, Normal mode, per channel 150 Vpeak
Maximum Output Current, Normal mode, per channel 41 Apeak
AMPLIFIER
Voltage Gain
Low-Z mode, ref. 1 kHz 32.0 dB, adjustable 20.0 — 44.0 dB
Direct Drive mode 33.2 / 36.2 / 39.2 / 42.2 dB for 70 / 100 / 140 / 200 V
Input Sensitivity
Low-Z mode, Max. Output Voltage 10.7 dBu (2.66 V), adjustable -1.3 — 22.7 dBu
Direct Drive mode 6 dBu (1.55 V), fixed
THD 3 dB below max, AES17, 1 kHz < 0.05 %
DIM 100 3.15 kHz, 15 kHz < 0.15 %
IMD-SMPTE, 60 Hz, 7 kHz < 0.05 %
Crosstalk ref. 1 kHz, 12 dB below Max, 8 Ω < -80 dB
Frequency Response, ref. 1 kHz, analog in to speaker out 20 Hz to 20 kHz (±0.5 dB)
Damping Factor, 20 Hz to 200 Hz, 8 ± > 400
Output Stage Topology Class D, fixed frequency
Signal to Noise Ratio Amplifier
A-weighted, analog input 112 dB
A-weighted, digital input 115 dB
Output Noise
A-weighted, analog input < -70 dBu
A-weighted, digital input < -73 dBu
CONNECTIVITY
Analog Audio Input/Thru
Type 2 x 6-pin Euroblock, male
Maximum Input Level +21 dBu
Input Impedance, active balanced 20 ㏀
Reference level equal to digital input +21 dBu for 0 dBFS
Speaker Output 1 x 8-pin Euroblock, 6mm, female
GENERAL
Power Consumption
Rated power consumption (see BTU table) 700 W
⅛ Maximum Output Power at 4 Ω 900 W
Idle Mode (no input signal) 75 W
Standby Mode < 15 W
Dimensions (W x H x D), mm 483 x 88.1 x 514.2
Weight 14.3 kg (31.5 lb)
Shipping Weight 16.5 kg (36.4 lb)
DIGITAL SIGNAL PROCESSING
Sampling Rate 48 kHz / 96 kHz, OMNEO/Dante synchronized
Signal delay/latency Analog In to Speaker Out, 48 kHz/96 kHz 0.70 ms / 0.53 ms
Dante Network Latency typ. 1.00 ms
Signal Processing
User EQ 12 filters per channel, selectable as PEQ, LoShelv, Hi-Shelv, Lo-ShelvQ, Hi-ShelvQ, HiPass, Lo-Pass & Notch; 2 filters of them with additional asymmetric filter type
User Delay 0 to 2000 ms per channel (units: µs, ms, s, cm, m, inches, feet)
Array EQ 5 filters per channel, selectable as PEQ, LoShelv, Hi-Shelv, LoShelvQ, HiShelvQ, Hi-Pass, Lo-Pass & All-Pass
Array Delay 0 to 500 ms per channel (units: µs, ms, s, cm, m, inches, feet)
Speaker EQ 10 filters per channel, selectable as PEQ, LoShelv, Hi-Shelv, Hi-Pass, Lo-Pass & All-Pass
Speaker X-Over Hi-Pass, & Lo-Pass per dB channel, 6/12/18/24/30/36/42/48 dB Bessel/ Butterworth, 12/24/48 Linkwitz-Riley; Alignment Delay, 0 to 20 ms per channel
Speaker FIR Up to 1025 taps, Linear Phase Filter, Linear Phase Brickwall X-Over
Speaker Limiters Peak Anticipation Limiter & RMS/TEMP Limiter per channel
Other Functions Source Selection & Mix, Level, Mute, Polarity, Sine & Noise Generator, Pilot Tone Generator & Detection, Level Meters, Impedance Measurement & Load Monitoring
Memory
DSP Presets 1 factory preset + 20 user presets
Speaker-Pool Presets 30 speaker settings
Source Supervision & Fallback Pilot Tone supervision at Analog & OMNEO/Dante inputs, switchover to alternative Source Selection
CONNECTIVITY
Network
Type 2 x Neutrik EtherCON/RJ45, redundant PRIMARY/SECONDARY
General 1000base-T/100base-TX, integrated switch
Network Audio Inputs 8 channels, 48/96 kHz, OMNEO/Dante format
Network Audio Outputs (Monitor) 2 channels, 48/96 kHz, OMNEO/Dante format
Mains Input 1 x Neutrik powerCON-HC
GPIO Control Port
Type 1 x 8-pin Euroblock, male
Ports & Operating Modes 3 x GPIO, switchable Analog In/Digital In/Digital Out
Analog Input Range 0 V to +13 V, 40 ㏀ input resistance
Digital Input Limits ON: < 1.5 V /
OFF: > 2.0 V, internal Pull Up (10 ㏀)
Digital Outputs ON: Output switched to GND, max. 200 mA
OFF: Open Collector (40 ㏀ to GND)
Reference Voltage Output +10 V, max. 200 mA, supervised, short circuit protected
READY/FAULT contact Galvanic isolated relay, max. 30 VDC/500 mADC
GENERAL
User Interface
Display Black/white OLED 256 x 64
Front panel indicators 4 x status LEDs (POWER, STANDBY, FAULT, OMNEO)
Front panel operating elements 3 buttons (UP, ENTER, DOWN)
Rear panel indicators 1 x status LED (STATUS)
Rear panel operating elements Mains Switch
Power Requirements 100 V to 240 V, 50 Hz to 60 Hz AC
Power Supply Topology Switching Mode Power Supply with digital controlled Power Factor Correction
Protections Audio Limiters, High Temperature, DC, HF, Short Circuit, Back-EMF, Peak Current Limiters, Inrush Current Limiters, Turn-on Delay, Mains Circuit Breaker Protection, Mains Over-/Under voltage Protection
Cooling Front-to-rear, temperature controlled fans, supervised
Ambient Temperature Limits +5 °C to +40 °C (+40 °F to +105 °F)
IEC Protection Class Class I (grounded)
Electromagnetical Environment E1, E2, E3
Color Black
Amplifier at rated conditions, Low-Z Normal operation mode, all channels driven, 4 Ω loads, Analog input, 32 dB Gain, 48 kHz sample rate, unless otherwise specified
1Test signal for max. output power according IHFA-202 (Dynamic-Headroom, burst 1 kHz / 20 ms on / 480 ms off / low level -20 dB).
2Available in Bridged operation mode only.

Videos

Downloads

Technical Documentations
Name Language & Download
IPX 5_4 A&E Specification
Name Language & Download
IPX Amplifier Series EC Declaration of Conformity
IPX Series EU Declaration of Conformity
Name Language & Download
IPX5:4 Engineering Data Sheet
Name Language & Download
IPX Series Installation Manual
Mains Operation & Resulting Temperature Table & Mains Fusing IPX-Series Amplifiers
IPX Series DSP Multichannel Networking Power Amplifier
IPX Series Guide
IPX Series Manual
IPX Series マニュアル
IPX Series 설치 매뉴얼
Name Language & Download
EN54 ProSound Q&A certification
Name Language & Download
Service Policies for Asia/Pacific Rim
Service Policies for China
Warranty conditions for Dynacord products in Europe, the Middle East, & Africa
Warranty conditions for Dynacord products in North America
Software, Firmware & Design Tools
Name Language & Download
IPX Series CAD Drawing
Name Language & Download
Firmware for SONICUE devices
Name Language & Download
SONICUE 1.4
SONICUE 1.3.1
How to upgrade Dynacord L- and C Series amplifiers firmware to SONICUE
Loudspeaker Settings for SONICUE
Marketing Materials
Name Language & Download
Audio Solution References for Sports Venues
Dynacord Amplifiers, Digital Audio Matrices & Software Catalog
IPX Brochure

Let's talk

Dynacord & Electro-Voice, together with our certified partners, are ready to help support you through planning, purchase, and setup. Services available through our network of highly-qualified associates and partners may include:

  • System Design
  • Installation
  • Programming & Commissioning

Find your local contact

Warranty & After Sales Programs

Compatible Products

Similar Products

sprites_global sprites_ev